1.
J Cardiovasc Electrophysiol ; 35(5): 1050-1054, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38501328

RESUMO

INTRODUCTION: Tricuspid regurgitation is associated with significant morbidity and mortality, and occurs at a higher rate in patients with cardiovascular implantable electronic devices. Percutaneous strategies for managing tricuspid regurgitation are evolving, including the development of bicaval valve implantation which has been successfully used in patients with pacing leads. METHODS AND RESULTS: We present the first documented case of lead failure following TricValve® implantation, a dedicated self-expanding system for bicaval valve implantation, and the first successful lead revision procedure in this setting. CONCLUSION: The case illustrates important considerations in undertaking percutaneous intervention in patients with cardiovascular implantable electronic devices, and their ongoing management.


Assuntos
Desfibriladores Implantáveis , Falha de Equipamento , Insuficiência da Valva Tricúspide , Humanos , Insuficiência da Valva Tricúspide/cirurgia , Insuficiência da Valva Tricúspide/fisiopatologia , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/efeitos adversos , Masculino , Idoso , Resultado do Tratamento , Reoperação , Desenho de Prótese , Remoção de Dispositivo , Feminino , Cardioversão Elétrica/instrumentação , Cardioversão Elétrica/efeitos adversos
2.
Open Heart ; 11(1)2024 Mar 08.
Artigo em Inglês | MEDLINE | ID: mdl-38458770

RESUMO

The wearable cardioverter defibrillator (WCD) is becoming a more and more widely used instrument for the prevention of sudden cardiac death of patients either with a secondary prevention implantable cardioverter defibrillator indication or with a transient high risk of sudden cardiac death. Although clinical practice has demonstrated a benefit of protecting patients for a period as long as 3-6 months with such devices, the current European guidelines concerning ventricular arrhythmias and sudden cardiac death are still extremely restrictive in the patient selection in part because of the costs derived from such a prevention device, in part because of the lack of robust randomised trials.To illustrate expanded use cases for the WCD, four real-life clinical cases are presented where patients received the device slightly outside the established guidelines. These cases demonstrate the broader utility of WCDs in situations involving acute myocarditis, thyrotoxicosis, pre-excited atrial fibrillation and awaiting staging/prognosis of a lung tumour. The findings prompt expansion of the existing guidelines for WCD use to efficiently protect more patients whose risk of arrhythmic cardiac death is transient or uncertain. This could be achieved by establishing a European register of the patients who receive a WCD for further analysis.


Assuntos
Fibrilação Atrial , Desfibriladores Implantáveis , Dispositivos Eletrônicos Vestíveis , Humanos , Cardioversão Elétrica/efeitos adversos , Morte Súbita Cardíaca/etiologia , Morte Súbita Cardíaca/prevenção & controle , Fibrilação Atrial/complicações
3.
Heart Rhythm ; 21(4): 410-418, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38246594

RESUMO

BACKGROUND: Outcome comparisons among subcutaneous implantable cardioverter-defibrillator (S-ICD) recipients with nonischemic cardiomyopathies are scarce. OBJECTIVE: The aim of this study was to evaluate differences in device-related outcomes among S-ICD recipients with different structural substrates. METHODS: Patients enrolled in the i-SUSI (International SUbcutaneouS Implantable cardioverter defibrillator registry) project were grouped according to the underlying substrate (ischemic vs nonischemic) and subgrouped into dilated cardiomyopathy, hypertrophic cardiomyopathy, Brugada syndrome (BrS), arrhythmogenic right ventricular cardiomyopathy (ARVC). The main outcome of our study was to compare the rates of appropriate and inappropriate shocks and device-related complications. RESULTS: Among 1698 patients, the most common underlying substrate was ischemic (31.7%), followed by dilated cardiomyopathy (20.5%), BrS (10.8%), hypertrophic cardiomyopathy (8.5%), and ARVC (4.4%). S-ICD for primary prevention was more common in the nonischemic cohort (70.9% vs 65.4%; P = .037). Over a median (interquartile range) follow-up of 26.5 (12.6-42.8) months, no differences were observed in appropriate shocks between ischemic and nonischemic patients (4.8%/y vs 3.9%/y; log-rank, P = .282). ARVC (9.0%/y; hazard ratio [HR] 2.492; P = .001) and BrS (1.8%/y; HR 0.396; P = .008) constituted the groups with the highest and lowest rates of appropriate shocks, respectively. Device-related complications did not differ between groups (ischemic: 6.4%/y vs nonischemic: 6.1%/y; log-rank, P = .666), nor among underlying substrates (log-rank, P = .089). Nonischemic patients experienced higher rates of inappropriate shocks than did ischemic S-ICD recipients (4.4%/y vs 3.0%/y; log-rank, P = .043), with patients with ARVC (9.9%/y; P = .001) having the highest risk, even after controlling for confounders (adjusted HR 2.243; confidence interval 1.338-4.267; P = .002). CONCLUSION: Most S-ICD recipients were primary prevention nonischemic cardiomyopathy patients. Among those, patients with ARVC tend to receive the most frequent appropriate and inappropriate shocks and patients with BrS the least frequent appropriate shocks.


Assuntos
Displasia Arritmogênica Ventricular Direita , Cardiomiopatias , Cardiomiopatia Dilatada , Desfibriladores Implantáveis , Humanos , Desfibriladores Implantáveis/efeitos adversos , Morte Súbita Cardíaca/epidemiologia , Morte Súbita Cardíaca/etiologia , Morte Súbita Cardíaca/prevenção & controle , Cardioversão Elétrica/efeitos adversos , Displasia Arritmogênica Ventricular Direita/complicações , Cardiomiopatia Dilatada/complicações , Cardiomiopatia Dilatada/terapia , Sistema de Registros , Resultado do Tratamento
4.
J Cardiovasc Electrophysiol ; 34(1): 225-228, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36511471

RESUMO

Intrinsic antitachycardia pacing (iATP) is a novel automated ventricular ATP algorithm that designs ATP sequences based on the analysis of prior failed ATP. Real-world data on the efficacy and safety of iATP are lacking. Among 124 ventricular tachycardia (VT) episodes in 130 consecutive patients (mean age at implantation: 63.8 ± 14.9 years; sex, 95 male and 35 female) for whom implantable cardioverter defibrillator or cardiac resynchronization therapy defibrillator equipped with iATP algorithm was implanted, we investigated the efficacy and safety of iATP for VT refractory to conventional burst pacing. Eight patients had a total of 17 episodes of iATP therapy after failed conventional burst pacing within 11.2 ± 6.6 months of follow-up. Eleven VT episodes (64.7%) in seven patients (87.5%) were successfully terminated by iATP, and only one patient (12.5%) experienced VT acceleration. iATP might be useful for VTs refractory to conventional burst pacing with a low risk of VT acceleration.


Assuntos
Terapia de Ressincronização Cardíaca , Desfibriladores Implantáveis , Taquicardia Ventricular , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/terapia , Estimulação Cardíaca Artificial/efeitos adversos , Terapia de Ressincronização Cardíaca/efeitos adversos , Cardioversão Elétrica/efeitos adversos , Trifosfato de Adenosina
5.
J Interv Card Electrophysiol ; 66(6): 1359-1366, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-36422768

RESUMO

BACKGROUND: While ICD therapy reduction programming strategies are recommended in current multi-society guidelines, concerns remain about a possible trade-off between the benefits of ICD therapy reduction and failure to treat episodes of ventricular arrhythmias. The study is to evaluate the outcomes of primary prevention patients followed in centers with high and low concordance with the 2015 HRS/EHRA/APHRS/SOLAECE expert consensus statement and 2019 focused update on optimal ICD programming and testing guidelines. METHODS: Consecutive patients with primary prevention ICD implantation from two centers between 2014 and 2016 were included. One center was classified as high guideline concordance center (HGC) with 47% (146/310) of patients with initial ICD concordant with the guidelines, and the other center was classified as low guideline concordance center (LGC) with only 1% (2/178) of patients with guideline-concordant initial ICD programming. Cox proportional hazard models were used to assess risk of first ICD therapy (ATP or shock), first ICD shock, and mortality. RESULTS: A total of 488 patients were included (mean age, 66 ± 13 years). During a mean follow-up of 1.9 ± 0.9 years, patients followed at HGC were 63% less likely to receive any ICD therapy (adjusted HR [aHR] 0.37, 95% CI 0.42-0.99). There were no significant differences in the rate of first ICD shock (aHR 0.72, 95% CI 0.34-1.52) or mortality (aHR 1.19, 95% CI, 0.47-3.05). CONCLUSIONS: Compared to primary prevention patients followed at LGC, primary prevention ICD patients followed at HGC received a significantly lower rate of ICD therapy, mainly from ATP reduction, without a difference in mortality during follow-up.


Assuntos
Desfibriladores Implantáveis , Humanos , Pessoa de Meia-Idade , Idoso , Desfibriladores Implantáveis/efeitos adversos , Cardioversão Elétrica/efeitos adversos , Arritmias Cardíacas/terapia , Trifosfato de Adenosina , Prevenção Primária , Morte Súbita Cardíaca/prevenção & controle , Morte Súbita Cardíaca/etiologia
6.
Curr Probl Cardiol ; 48(4): 101571, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36584731

RESUMO

Cardiac amyloidosis (CA) is a restrictive disease that results from intramyocardial amyloid deposition due to immunoglobulin light chain or transthyretin proteins. Up to two-third of CA patients have atrial fibrillation (AF) due to electromechanical, autonomic, and hemodynamic disturbances. AF in CA carries particularly increased risk of thromboembolism, prompting anticoagulation therapy irrespective of CHA2DS2VASc score. However, CA is also associated with enhanced bleeding risk that warrants thorough assessment of bleeding profile before initiation of anticoagulation. Management of AF in CA is challenging because these patients poorly tolerate rate control agents, while cardiomyopathy precludes most antiarrhythmic agents, leaving amiodarone as the preferred antiarrhythmic drug. The effectiveness of direct current cardioversion in restoring sinus rhythm in CA is comparable with that in the general population, although intraprocedural complication rates could be higher. Transesophageal echocardiogram should be performed prior to direct current cardioversion, given high incidence of intracardiac thrombus in these patients. Finally, the data on catheter ablation is limited.


Assuntos
Amiloidose , Fibrilação Atrial , Tromboembolia , Trombose , Humanos , Fibrilação Atrial/complicações , Antiarrítmicos/uso terapêutico , Tromboembolia/tratamento farmacológico , Trombose/tratamento farmacológico , Cardioversão Elétrica/efeitos adversos , Amiloidose/complicações
7.
Ear Nose Throat J ; 102(5): NP229-NP231, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-33734884

RESUMO

Hearing loss in older people can cause communication impairments, decreased quality of life, social isolation, depression, and dementia. Cochlear implant surgery is an effective treatment for older patients with hearing loss who cannot achieve satisfactory audiologic outcomes with hearing aids. However, older people have an increased risk of heart disease and often take medications that affect heart rhythm. Herein, we report a case of an 80-year-old woman who underwent cardioversion at 50J after cochlear implant surgery. Electrical impedance before and after cardioversion showed only minor changes without abnormality, and the cochlear implant functioned well. We believe that the electronic circuits of the cochlear implant may have been relatively tolerant to the electrical shock from the external defibrillator. Typically, cardioversion should be avoided in cochlear implant recipients because it may damage the implant. If cardioversion cannot be avoided, we strongly recommend starting cardioversion at the lowest energy level (50 J) and removing the sound processor of the implant during the procedure.


Assuntos
Flutter Atrial , Implantes Cocleares , Surdez , Perda Auditiva , Feminino , Humanos , Idoso , Idoso de 80 Anos ou mais , Cardioversão Elétrica/efeitos adversos , Cardioversão Elétrica/métodos , Flutter Atrial/etiologia , Qualidade de Vida , Arritmias Cardíacas/etiologia , Perda Auditiva/etiologia
8.
J Cardiol ; 80(6): 573-577, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-35985868

RESUMO

BACKGROUND: The wearable cardioverter defibrillator (WCD) is increasingly used in patients at elevated risk for ventricular arrhythmias but not fulfilling the indications for an implantable cardioverter defibrillator (ICD). Currently, there is an insufficient risk prediction of fatal arrhythmias in patients at risk. In this study, we assessed the prognostic role of baseline electrocardiogram (ECG) in WCD patients. METHODS: WCD patients from diverse clinical institutions in Germany (n = 227) were retrospectively enrolled and investigated for the incidences of death or ventricular arrhythmias during WCD wearing. In addition, the widely accepted ECG predictors of adverse outcome were analyzed in patients with arrhythmic events. RESULTS: Life-threatening arrhythmias occurred in 22 (9.7 %) patients, mostly in subjects with ischemic heart disease (15 of 22). There was no difference in baseline left ventricular ejection fraction (LVEF) in subjects with and without arrhythmic events (31.3 ±â€¯7.9 % vs. 32.6 ±â€¯8.3 %; p = 0,24). Patients with arrhythmia exhibited significantly longer QRS duration (109.5 ±â€¯23.1 ms vs. 100.6 ±â€¯22.3 ms, p = 0,04), Tpeak-Tend (Tp-e) (103.1 ±â€¯15.6 ms vs. 93.2 ±â€¯19.2 ms, p = 0,01) and QTc (475.0 ±â€¯60.0 ms vs. 429.6 ±â€¯59.4 ms, p < 0,001) intervals. In contrast, no significant differences were found for incidences of fragmented QRS (27.3 % vs. 24 %, p = 0.79) and inverted/biphasic T-waves (16.6 % vs. 22.7 %, p = 0,55). In multivariate regression analysis both Tp-e (HR 1.03; 95 % CI 1.001-1.057; p = 0.02) and QTc (HR 1.02; 95 % CI 1.006-1.026; p < 0.001) were identified as independent predictors of ventricular arrhythmias. After WCD use, the prophylactic ICD was indicated in 76 patients (33 %) with uneventful clinical course but persistent LVEF ≤35 %. The ECG analysis in these subjects did not reveal any relevant changes in arrhythmogenesis markers. CONCLUSIONS: ECG repolarization markers Tp-e and QTc are associated with malignant arrhythmias in WCD patients and may be used - in addition to other established risk markers - to identify appropriate patients for ICD implantation.


Assuntos
Desfibriladores Implantáveis , Dispositivos Eletrônicos Vestíveis , Humanos , Morte Súbita Cardíaca/epidemiologia , Morte Súbita Cardíaca/etiologia , Morte Súbita Cardíaca/prevenção & controle , Volume Sistólico , Estudos Retrospectivos , Função Ventricular Esquerda , Cardioversão Elétrica/efeitos adversos , Desfibriladores Implantáveis/efeitos adversos , Eletrocardiografia , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/etiologia , Arritmias Cardíacas/terapia , Dispositivos Eletrônicos Vestíveis/efeitos adversos , Medição de Risco
9.
ESC Heart Fail ; 9(5): 3556-3564, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35903879

RESUMO

AIMS: Atrial fibrillation (AF)/atrial flutter is common during cardiac amyloidosis (CA). Electrical cardioversion (EC) is a strategy to restore sinus rhythm (SR). However, left atrial thrombus (LAT) represents a contraindication for EC. CA patients with AF/atrial flutter have a high prevalence of LAT. We aimed to evaluate EC characteristics, LAT prevalence and risk factors, and AF/atrial flutter outcome in CA patients undergoing EC, predominantly treated with direct oral anticoagulants (DOACs). METHODS AND RESULTS: All patients with CA and AF/atrial flutter referred for the first time to our national referral centre of amyloidosis for EC from June 2017 to February 2021 were included in this study. In total, 66 patients (median age 74.5 [70;80.75] years, 67% male) were included with anticoagulation consisted of DOAC in 74% of cases. All patients underwent cardiac imaging before EC to rule out LAT. EC was cancelled due to LAT in 14% of cases. Complete thrombus resolution was observed in only 17% of cases. The two independent parameters associated with LAT were creatinine [hazard ratio (HR) = 1.01; confidence interval (CI) = 1.00-1.03, P = 0.036] and the use of antiplatelet agents (HR = 13.47; CI = 1.85-98.02). EC acute success rate was 88%, and we observed no complication after EC. With 64% of patients under amiodarone, AF/atrial flutter recurrence rate following EC was 51% after a mean follow-up of 30 ± 27 months. CONCLUSIONS: Left atrial thrombus was observed in 14% of CA patients listed for EC and mainly treated with DOAC. The acute EC success rate was high with no complication. The long-term EC success rate was acceptable (49%).


Assuntos
Amiloidose , Fibrilação Atrial , Flutter Atrial , Cardiopatias , Trombose , Humanos , Masculino , Idoso , Feminino , Cardioversão Elétrica/efeitos adversos , Cardioversão Elétrica/métodos , Flutter Atrial/complicações , Flutter Atrial/terapia , Fibrilação Atrial/complicações , Fibrilação Atrial/terapia , Trombose/etiologia , Amiloidose/complicações , Amiloidose/diagnóstico , Amiloidose/terapia
10.
Europace ; 24(2): 306-312, 2022 02 02.
Artigo em Inglês | MEDLINE | ID: mdl-34279601

RESUMO

AIMS: Treatment with implantable cardioverter-defibrillators (ICD) is a cornerstone for prevention of sudden cardiac death in arrhythmogenic right ventricular cardiomyopathy (ARVC). We aimed at describing the complications associated with ICD treatment in a multinational cohort with long-term follow-up. METHODS AND RESULTS: The Nordic ARVC registry was established in 2010 and encompasses a large multinational cohort of ARVC patients, including their clinical characteristics, treatment, and events during follow-up. We included 299 patients (66% males, median age 41 years). During a median follow-up of 10.6 years, 124 (41%) patients experienced appropriate ICD shock therapy, 28 (9%) experienced inappropriate shocks, 82 (27%) had a complication requiring surgery (mainly lead-related, n = 75), and 99 (33%) patients experienced the combined endpoint of either an inappropriate shock or a surgical complication. The crude rate of first inappropriate shock was 3.4% during the first year after implantation but decreased after the first year and plateaued over time. Contrary, the risk of a complication requiring surgery was 5.5% the first year and remained high throughout the study period. The combined risk of any complication was 7.9% the first year. In multivariate cox regression, presence of atrial fibrillation/flutter was a risk factor for inappropriate shock (P < 0.05), whereas sex, age at implant, and device type were not (all P > 0.05). CONCLUSION: Forty-one percent of ARVC patients treated with ICD experienced potentially life-saving ICD therapy during long-term follow-up. A third of the patients experienced a complication during follow-up with lead-related complications constituting the vast majority.


Assuntos
Displasia Arritmogênica Ventricular Direita , Desfibriladores Implantáveis , Adulto , Displasia Arritmogênica Ventricular Direita/complicações , Displasia Arritmogênica Ventricular Direita/diagnóstico , Displasia Arritmogênica Ventricular Direita/terapia , Morte Súbita Cardíaca/etiologia , Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis/efeitos adversos , Cardioversão Elétrica/efeitos adversos , Feminino , Humanos , Masculino , Sistema de Registros , Fatores de Risco , Resultado do Tratamento
11.
In. Soeiro, Alexandre de Matos; Leal, Tatiana de Carvalho Andreucci Torres; Accorsi, Tarso Augusto Duenhas; Gualandro, Danielle Menosi; Oliveira Junior, Múcio Tavares de; Caramelli, Bruno; Kalil Filho, Roberto. Manual da residência em cardiologia / Manual residence in cardiology. Santana de Parnaíba, Manole, 2 ed; 2022. p.545-547, tab.
Monografia em Português | LILACS | ID: biblio-1352997
12.
J Cardiovasc Surg (Torino) ; 62(5): 510-514, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-33829746

RESUMO

BACKGROUND: Patients with tricuspid valve (TV) disease and indication for TV surgery frequently have permanent pacemaker (PM) or defibrillator (AICD) leads, placed in the right ventricle (RV). The aim of this study was to analyze postoperative results and mid-term outcomes after isolated TV surgery (with no further concomitant cardiac procedures) in the presence of permanent RV leads. METHODS: From January 2005 to January 2019 a total of 80 patients (mean age: 67.7±10.3 yrs; 56.3% male) with isolated TV disease and presence of at least one permanent RV lead in place were referred to our institution for isolated TV repair/replacement; patients with concomitant procedures were excluded for this analysis. All data were retrospectively analyzed. The follow-up was 98% complete. RESULTS: Mean follow-up time was 4.3±3.9 years. Mean preoperative clinical NYHA status was 3.0±0.8, left ventricular ejection fraction 50.7±12.9%, mean pulmonary artery pressure 23.8±9.3mmHg, creatinine 125.7±57.5µmol/L, mean MELD-XI Score (Model of End-stage-Liver Disease excluding INR) was 14.6±5.0 µmol/L. Thirty-day mortality was 6.3% with a 5-years survival of 58.2±6.0%. Cox regression analysis revealed the MELD-XI-Score as the only highly significant predictor for postoperative mortality (P=0.002). CONCLUSIONS: Hepatorenal dysfunction - possibly indicating long lasting TV failure - could be a factor for limited postoperative survival in our patient cohort. This finding could underline our hypothesis, that early TV surgery may achieve better postoperative survival, even in patients with TV disease caused by RV leads. Therefore, further investigations are needed.


Assuntos
Estimulação Cardíaca Artificial , Desfibriladores Implantáveis , Cardioversão Elétrica/instrumentação , Marca-Passo Artificial , Insuficiência da Valva Tricúspide/cirurgia , Valva Tricúspide/cirurgia , Idoso , Estimulação Cardíaca Artificial/efeitos adversos , Estimulação Cardíaca Artificial/mortalidade , Desfibriladores Implantáveis/efeitos adversos , Cardioversão Elétrica/efeitos adversos , Cardioversão Elétrica/mortalidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Marca-Passo Artificial/efeitos adversos , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/fisiopatologia , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Insuficiência da Valva Tricúspide/mortalidade , Insuficiência da Valva Tricúspide/fisiopatologia
13.
PLoS One ; 16(4): e0250353, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33886660

RESUMO

INTRODUCTION: Atrial fibrillation (AF) comes along with high risk of stroke. This risk continues even after re-establishing sinus rhythm with cardioversion. Aim of this study is to evaluate the contribution of electric cardioversion (EC) to platelet activation and procoagulatory tendency. METHODS: Extent of platelet activation before and after electric cardioversion was quantified using flow cytometry, impedance aggregation measurements with Multiplate®, and quantification of serum levels of platelet factor 4 (PF4) and ß-thromboglobulin (ß-TG) in patients with AF (N = 10). RESULTS: No significant differences were observed in any of the measured parameters comparing the values from before and after cardioversion. Geometric means of P-selectin expression and integrin αIIbß3 activation were 0.27 (+/- 0.07) and 2.30 (+/- 2.61) before EC and 0.28 (+/- 0.17) and 1.67 (+/- 1.82) after EC. Levels of ß-TG were 110.11 ng/ml (+/- 3.78) before and 110.51 ng/ml (+/- 2.56) after EC, levels of PF4 were 35.64 ng/ml (+/- 12.94) before and 32.40 ng/ml (+/- 4.95) after EC. Platelet aggregation triggered with adenosine diphosphate (ADP), arachidonic acid, collagen, Ristocetin, or thrombin receptor activating peptide (TRAP) revealed results within the normally expected ranges without significant changes before and after EC. DISCUSSION: Electric cardioversion has no influence on platelet activation markers which is in agreement with other studies reporting electrical cardioversion to be safe.


Assuntos
Fibrilação Atrial/terapia , Cardioversão Elétrica/efeitos adversos , Ativação Plaquetária , Agregação Plaquetária , Difosfato de Adenosina/farmacologia , Adulto , Idoso , Ácido Araquidônico/farmacologia , Fibrilação Atrial/sangue , Coagulação Sanguínea/efeitos dos fármacos , Colágeno/farmacologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Fragmentos de Peptídeos/farmacologia , Ativação Plaquetária/efeitos dos fármacos , Agregação Plaquetária/efeitos dos fármacos , Fator Plaquetário 4/sangue , Testes de Função Plaquetária/métodos , Ristocetina/farmacologia , Resultado do Tratamento
14.
Circ Arrhythm Electrophysiol ; 14(3): e007954, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-33685207

RESUMO

Orthotropic heart transplantation remains the most effective therapy for patients with end-stage heart failure, with a median survival of ≈13 years. Yet, a number of complications are observed after orthotropic heart transplantation, including atrial and ventricular arrhythmias. Several factors contribute to arrhythmias, such as autonomic denervation, effect of the surgical technique, acute and chronic rejection, and transplant vasculopathy among others. To minimize risk of future arrhythmias, the bicaval technique and minimizing ischemic time are current surgical standards. Sinus node dysfunction is the most common indication for early (within 30 days) pacemaker implantation, whereas atrioventricular block incidence increases as time from transplant increases. Atrial fibrillation can occur in the first few weeks following transplantation but is uncommon in the long term unless secondary to a precipitant such as acute rejection. The most common atrial arrhythmias are atrial flutters, which are mainly typical, but atypical circuits can be observed such as those that involve the remnant donor atrium in regions immediately adjacent to the atrioatrial anastomosis suture line. Choosing the appropriate pharmacological therapy requires careful consideration due to the potential interaction with immunosuppressive agents. Despite historical concerns, adenosine is effective and safe at reduced doses if administered under cardiac monitoring. Catheter ablation has emerged as an effective treatment strategy for symptomatic supraventricular tachycardias, including ablation of atypical flutter circuits. Cardiac allograft vasculopathy is an important risk factor for sudden cardiac death, yet the role of prophylactic implantable cardioverter-defibrillator implant for sudden death prevention is unclear. Current indications for implantable cardioverter-defibrillator implantation are as in the nontransplant population. A number of questions for future research are posed.


Assuntos
Antiarrítmicos/uso terapêutico , Arritmias Cardíacas/terapia , Ablação por Cateter , Cardioversão Elétrica , Frequência Cardíaca/efeitos dos fármacos , Transplante de Coração/efeitos adversos , Potenciais de Ação , Animais , Antiarrítmicos/efeitos adversos , Arritmias Cardíacas/etiologia , Arritmias Cardíacas/mortalidade , Arritmias Cardíacas/fisiopatologia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/mortalidade , Desfibriladores Implantáveis , Cardioversão Elétrica/efeitos adversos , Cardioversão Elétrica/instrumentação , Cardioversão Elétrica/mortalidade , Transplante de Coração/mortalidade , Humanos , Fatores de Risco , Resultado do Tratamento
15.
J Am Heart Assoc ; 10(7): e018063, 2021 04 06.
Artigo em Inglês | MEDLINE | ID: mdl-33787324

RESUMO

Background One third of primary prevention implantable cardioverter-defibrillator patients receive appropriate therapy, but all remain at risk of defibrillator complications. Information on these complications in contemporary cohorts is limited. This study assessed complications and their risk factors after defibrillator implantation in a Dutch nationwide prospective registry cohort and forecasts the potential reduction in complications under distinct scenarios of updated indication criteria. Methods and Results Complications in a prospective multicenter registry cohort of 1442 primary implantable cardioverter-defibrillator implant patients were classified as major or minor. The potential for reducing complications was derived from a newly developed prediction model of appropriate therapy to identify patients with a low probability of benefitting from the implantable cardioverter-defibrillator. During a follow-up of 2.2 years (interquartile range, 2.0-2.6 years), 228 complications occurred in 195 patients (13.6%), with 113 patients (7.8%) experiencing at least one major complication. Most common ones were lead related (n=93) and infection (n=18). Minor complications occurred in 6.8% of patients, with lead-related (n=47) and pocket-related (n=40) complications as the most prevailing ones. A surgical reintervention or additional hospitalization was required in 53% or 61% of complications, respectively. Complications were strongly associated with device type. Application of stricter implant indication results in a comparable proportional reduction of (major) complications. Conclusions One in 13 patients experiences at least one major implantable cardioverter-defibrillator-related complication, and many patients undergo a surgical reintervention. Complications are related to defibrillator implantations, and these should be discussed with the patient. Stricter implant indication criteria and careful selection of device type implanted may have significant clinical and financial benefits.


Assuntos
Morte Súbita Cardíaca , Desfibriladores Implantáveis , Cardioversão Elétrica , Complicações Pós-Operatórias , Implantação de Prótese/efeitos adversos , Idoso , Morte Súbita Cardíaca/epidemiologia , Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis/efeitos adversos , Desfibriladores Implantáveis/classificação , Desfibriladores Implantáveis/estatística & dados numéricos , Cardioversão Elétrica/efeitos adversos , Cardioversão Elétrica/instrumentação , Cardioversão Elétrica/métodos , Análise de Falha de Equipamento/métodos , Análise de Falha de Equipamento/estatística & dados numéricos , Feminino , Humanos , Masculino , Avaliação das Necessidades , Países Baixos/epidemiologia , Seleção de Pacientes , Complicações Pós-Operatórias/diagnóstico , Complicações Pós-Operatórias/epidemiologia , Sistema de Registros/estatística & dados numéricos , Reoperação/estatística & dados numéricos , Medição de Risco , Fatores de Risco
16.
Arch Cardiovasc Dis ; 114(4): 287-292, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33526375

RESUMO

BACKGROUND: Reversion of an implantable cardioverter defibrillator (ICD) to back-up mode degrades the operating capabilities of the device, puts patients at risk and requires rapid intervention by a manufacturer's technician. AIM: To illustrate the usefulness of remote monitoring of ICDs for the early detection of reversion to back-up mode. METHODS: In our centre, all patients implanted with an ICD, with or without resynchronisation, were offered remote monitoring as soon as the technology became available. Alerts triggered by the remote monitoring system were included prospectively in a register. During a mean follow-up of 5.7±1.3 years, a total of 1594 patients with an ICD (441 with resynchronisation function) followed with remote monitoring were included in the register. RESULTS: Among 15,874 alerts, only 10 were related to a reversion to back-up mode. Among those, seven reversions were caused by radiotherapy, two were fake events and one was caused by magnetic resonance imaging. Except for the two fake events, the eight other patients had an emergency admission for the resetting and reprogramming of their ICD. None of the reversion to back-up mode alerts was followed by a clinical alert (i.e. a shock alert) before the ICD problem was resolved. CONCLUSIONS: Reversion to back-up mode is a very rare event, accounting for 0.06% of total alerts; remote monitoring facilitates the early detection of this critical event to resolve the problem faster than the next scheduled follow-up. Remote monitoring can prevent serious damage to the patient and avoids systematic ambulatory control of the ICD after each radiotherapy session.


Assuntos
Arritmias Cardíacas/terapia , Desfibriladores Implantáveis , Cardioversão Elétrica/instrumentação , Insuficiência Cardíaca/terapia , Falha de Prótese , Tecnologia de Sensoriamento Remoto , Telemedicina , Idoso , Idoso de 80 Anos ou mais , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/fisiopatologia , Diagnóstico Precoce , Cardioversão Elétrica/efeitos adversos , Feminino , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Sistema de Registros , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
17.
Heart Rhythm ; 18(2): 271-277, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-33031960

RESUMO

BACKGROUND: Recent research findings have revealed a key role of oxidative DNA damage in the pathogenesis of atrial fibrillation (AF). Therefore, the circulating oxidative DNA damage marker 8-hydroxy-2'-deoxyguanosine (8-OHdG) may represent a biomarker for staging AF and identifying patients at risk for AF recurrence and postoperative atrial fibrillation (POAF) after treatment. OBJECTIVE: The purpose of this study was to investigate whether serum levels of 8-OHdG correlate with the stage of AF, recurrence after AF treatment, and onset of POAF after cardiac surgery. METHODS: In this prospective observational study, 8-OHdG levels were detected by enzyme-linked immunosorbent assay in human serum samples. Blood samples were collected from control patients without AF history; patients with paroxysmal AF and persistent AF undergoing electrical cardioversion or pulmonary vein isolation (PVI); and patients with sinus rhythm (SR) undergoing cardiac surgery. AF recurrence was determined during 12-month follow-up. Univariate and multivariate analyses were used to identify changes in 8-OHdG levels between the groups. RESULTS: Compared to the control group, 8-OHdG levels in the patient groups gradually and significantly increased during arrhythmia progression. 8-OHdG levels in AF patients showing AF recurrence after PVI treatment were significantly increased compared to patients without AF recurrence. Moreover, in SR patients undergoing cardiac surgery, 8-OHdG levels were significantly elevated in those showing POAF compared to patients without POAF. CONCLUSION: 8-OHdG level may represent a potential diagnostic biomarker for AF staging as well as for predicting AF recurrence and POAF after treatment.


Assuntos
8-Hidroxi-2'-Desoxiguanosina/sangue , Fibrilação Atrial/diagnóstico , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Cardioversão Elétrica/efeitos adversos , Fibrilação Atrial/etiologia , Fibrilação Atrial/fisiopatologia , Biomarcadores/sangue , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico , Estudos Prospectivos , Resultado do Tratamento
18.
BMC Cardiovasc Disord ; 20(1): 455, 2020 10 21.
Artigo em Inglês | MEDLINE | ID: mdl-33087069

RESUMO

BACKGROUND: There is clear evidence that patients with prior myocardial infarction and a reduced ejection fraction benefit from implantation of a cardioverter-defibrillator (ICD). It is unclear whether this benefit is altered by whether or not revascularization is performed prior to ICD implantation. METHODS: This was a retrospective cohort study following patients who underwent ICD implantation from 2002 to 2014. Patients with ischemic cardiomyopathy and either primary or secondary prevention ICDs were selected for inclusion. Using the electronic medical record, cardiac catheterization data, revascularization status (percutaneous coronary intervention or coronary bypass surgery) were recorded. The outcomes were mortality and ventricular arrhythmia. RESULTS: There were 606 patients included in the analysis. The mean age was 66.3 ± 10.1 years, 11.9% were women, and the mean LVEF was 30.5 ± 12.0, 58.9% had a primary indication for ICD, 82.0% of the cohort had undergone coronary catheterization prior to ICD implantation. In the overall cohort, there were fewer mortality and ventricular arrhythmia events in patients who had undergone prior revascularization. In patients who had an ICD for secondary prevention, revascularization was associated with a decrease in mortality (HR 0.46, 95% CI (0.24, 0.85) p = 0.015), and a trend towards fewer ventricular arrhythmia (HR 0.62, 95% CI (0.38, 1.00) p = 0.051). There was no association between death or ventricular arrhythmia with revascularization in patients with primary prevention ICDs. CONCLUSION: Revascularization may be beneficial in preventing recurrent ventricular arrhythmia, and should be considered as adjunctive therapy to ICD implantation to improve cardiovascular outcomes.


Assuntos
Arritmias Cardíacas/prevenção & controle , Cardiomiopatias/terapia , Ponte de Artéria Coronária , Cardioversão Elétrica , Isquemia Miocárdica/terapia , Intervenção Coronária Percutânea , Idoso , Arritmias Cardíacas/etiologia , Arritmias Cardíacas/mortalidade , Cardiomiopatias/etiologia , Cardiomiopatias/mortalidade , Tomada de Decisão Clínica , Ponte de Artéria Coronária/efeitos adversos , Ponte de Artéria Coronária/mortalidade , Desfibriladores Implantáveis , Cardioversão Elétrica/efeitos adversos , Cardioversão Elétrica/instrumentação , Cardioversão Elétrica/mortalidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Isquemia Miocárdica/complicações , Isquemia Miocárdica/mortalidade , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Prevenção Primária , Sistema de Registros , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Prevenção Secundária , Fatores de Tempo , Resultado do Tratamento
19.
Rev Cardiovasc Med ; 21(3): 321-338, 2020 09 30.
Artigo em Inglês | MEDLINE | ID: mdl-33070538

RESUMO

Sarcoidosis is a chronic inflammatory disease of unknown etiology characterized by multi-organ involvement. End-organ disease consists of granulomatous inflammation, which if left untreated or not resolved spontaneously, leads to permanent fibrosis and end-organ dysfunction. Cardiac involvement and fibrosis in sarcoidosis occur in 5-10% of cases and is becoming increasingly diagnosed. This is due to increased clinical awareness among clinicians and new diagnostic modalities, since magnetic resonance imaging and positron-emission tomography are emerging as "gold standard" tools replacing endomyocardial biopsy. Despite this progress, isolated cardiac sarcoidosis is difficult to differentiate from other causes of arrhythmogenic cardiomyopathy. Cardiac fibrosis leads to congestive heart failure, arrhythmias and sudden cardiac death. Immunosuppressives (mostly corticosteroids) are used for the treatment of cardiac sarcoidosis. Implantable devices like a cardioverter-defibrillator may be warranted in order to prevent sudden cardiac death. In this article current trends in the pathophysiology, diagnosis and management of cardiac sarcoidosis will be reviewed focusing on published research and latest guidelines. Lastly, a management algorithm is proposed.


Assuntos
Corticosteroides/uso terapêutico , Cardiomiopatias/diagnóstico , Cardiomiopatias/terapia , Cardioversão Elétrica , Imunossupressores/uso terapêutico , Sarcoidose/diagnóstico , Sarcoidose/terapia , Cardiomiopatias/patologia , Cardiomiopatias/fisiopatologia , Morte Súbita Cardíaca/patologia , Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis , Cardioversão Elétrica/efeitos adversos , Cardioversão Elétrica/instrumentação , Fibrose , Humanos , Miocárdio/patologia , Fatores de Risco , Sarcoidose/patologia , Sarcoidose/fisiopatologia , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA